Features The ACE-C232 includes two ACE-R232A redundant power modules. The two power modules are parallel used. The ACE-C232 could be used in ICP Chassis, for example: RACK-305A, PAC-170, MPC-6010,...etc.
ACE-R232A 230W Redundant Power Module
Input: 90V to 130V AC or 180V to 260V AC selectable
Outputs (Max. Output Power 230W at 30oC)
Ripple and Noise: The peak to peak ripple and noise for +5V output is less than 50mV, for +/-12V and +5V output is less than 100mV. Line Regulation: The line regulation for each output is less +/-1% while measuring at rated load and +/-10% of 115V AC or 230V AC input voltage changing. Load
Regulation: The output voltage load regulation is less than the following
values by changing each output and +/-40% from 60% rated load, and keep
all other outputs at 60% rated load. Hold Up Time: >16ms Power Good Signal: Go high 100ms to 500ms after all output DC voltages are within regulation limits. Efficiency: 70% typical Output Protection: Over Voltage Protection and Short Protection Operating Temperature: 0oC ~ 50oC ( derating about 20% from 30oC to 50oC ) Storage Temperature: -40oC ~ 85oC Cooling: Cooling with a 42CFM forced air MTBF: 176,530Hrs Safety Standards: UL 1950, CSA22.2 No.234, EN 60950 EMI Standard: ECC docket 20780 curve " B ", EN55022 class " B " Connectors: ECC docket 20780 curve "B", EN55022 class "B" Connectors: DIN 41612 C96 Pin Assignment:
|
|
|
|
|