ACE-935
AC Input Industrial PS/2 Type Power Supply

Features
Input
Table :
Output
Table : (at 40%)
Inrush
Current
-ACE- 940AP: 80A(Peak) @115VAC or 120A(peak) @230VAC
- ACE- 935A/932A: Not exceed 15A@115V AC or 30A@230V AC
- ACE- 925A/925AP/920A/920AP: Not exceed 30A@115V AC or 60A@230V
AC
Ripple and Noise :
- ACE- 940AP: Less than 120mV @+12V and 3% of each output at rated
load
- ACE- 935A/932A: Less than 1% of each output at rated load
- ACE- 925A/925AP/920A/920AP: Less than 140mV@+12V, and 1% of each
other outputs at rated load
Line Regulation :
- ACE- 940AP: The line requlation for each outputs are less than
+/-5%
- ACE- 935A/932A: The line regulation for each outputs are less
than +/-1%
- ACE- 925A/925AP/920A/920AP/930AP: Less than +/-2%@+12V and +/-1%@Others
Efficiency : Higher than 65%
Hold-up Time:
- ACE-940AP: 17ms (typical) @115V AC
- ACE-935A/932A: 20ms (typical)@115V AC
- ACE-925A/925AP/920A/920AP: 14ms (typical)@115V AC
Altitude : 0 ~ 10,000ft
Protection :
- Over voltage protection. The trip point is around 5.7V ~ 7.0V
output
- Short circuit and overload
Vibration : 10 ~ 55Hz at 2G 3min. period, 30 min. along X, Y and
Z axis
Impact : 10G for 20ms once on each X, Y and Z axis
MTBF :
- ACE-935A : 200,050 Hours ?ACE-932A : 124,100 Hours
- ACE-925A : 204,100 Hours ?ACE-920A : 216,700 Hours
- ACE-940AP: 100000 Hours
Safety : Meets UL 1950; CSA 22.2 No. 234, VDE EN 60950
EMI :
- Meets FCC docket 20780 curve "B", EN555022 class "B"
- Harmonic EN 61000-3-2 for ACE-940AP/ACE-932AP/925AP/920AP, 930AP
at 230VAC
EMS Standard (Design to meet the following limits) : EN 50082-2
Operating Temperatured : -20ºC~70ºC/0ºC~40ºC(ACE-930A)/0ºC~50ºC
(940AP) (Derating curve will occur 50ºC~70ºC)
Storage Temperature : -40ºC~75ºC
|