ACE-890
Industrial 1U Power Supply

Features
Input
/ Output Table : (at 50ºC)
ACE-890AP:
min load + 5VDC/ 1.5A, + 12VDC, -12VDC/ 0.05A
Ripple and Noise : Less than +5V@50mV, +/-12V@100mV Less than +5V@100mV,
-12V@150mV, -12V@200mV (ACE-890AP)
Line Regulation : The line regulation for each output is less than
+/-1%, while measuring at rated loading and +/-10% of input voltage
changing
Load Regulation : Less than +/-1%@+5V and +/-5%@+/-12V
Efficiency : Higher than 70%
Hold-up Time (ACE-890A/890AP) : 16ms (typical)@115V AC
Protection : Over voltage protection. The trip point is around 5.7V~7.0V
output
Operating Temperature : -20ºC ~70ºC (Derating curve will
occur 50ºC ~70ºC)
Storage Temperature : -20ºC ~85 ºC
Altitude : 0~10,000ft
MTBF :
- ACE-890A : 268,358 Hours
- ACE-890P : 265,827 Hours
- ACE-890T : 269,884 Hours
- ACE-890C : 252,383 Hours
- ACE-890V : 245,424 Hours
- ACE-890AP : 50,000Hours
Safety : Meets UL 1950, CSA 22.2 No. 234, VDE EN 60 950
EMI :
- Meets FCC docket 20780 curve "B", EN55022 "B"
- Harmonic EN 61000-3-2 for ACE-890AP
EMS Standard (Designed to meet the following limits) :
- IEC 801-2 15KV (Air Discharge)
- IEC 801-3, 10V/M
- IEC 801-4, 2KV
- IEC 801-5, 2KV
Dimensions : 89(W) x 39(H) x 152.4(D)mm; (3.5" x 1.5"
x 6")
|