Industrial ATX Power Supply

Features

Input Table:

Output Table: (at 40ºC)

Ripple and Noise : Less than 50mV@+5V and +3.3V; 100mV@Others
Line Regulation : The line regulation for each outputs are less than ±1%
Load Regulation :

Output Power : Total combined output power on the +3.3V and +5V rails is 150W
Efficiency : Higher than 65%
Hold-up Time (ACE-828A/830AP) : 20ms (typical)@115V AC
Altitude : 0 ~ 10,000ft
Protection :
- Over voltage protection : The trip point is around
5.7V ~ 7.0V output
- Short circuit protection
Vibration : 10 ~ 55Hz at 2G 3min. period, 30 min. along X, Y and Z axis
Impact : 10G for 20ms once on each X, Y and Z axis
Built-in cooling fan
MTBF :
- ACE-828A : 101,379 Hours
- ACE-828C : 121,233 Hours
- ACE-828T : 112,112 Hours
- ACE-828V : 95,620 Hours
Safety : Meets UL 1950; CSA 22.2 No. 234, VDE EN 60950
EMI :
- Meets FCC class "B", EN55022 class "B"
- Harmonic EN 61000-3-2 for ACE-830AP
Operating Temperature : -20º ~ 70ºC
(Derating curve will occur 40º~ 70ºC)
Storage Temperature : -40º ~ 75ºC
EMS Standard (Designed to meet the following limits) :
- IEC 801-2 8KV (Air Discharge)
- IEC 801-3, 3V/M criteria A
- IEC 801-4, 2KV criteria B
- IEC 801-5, 2KV criteria B

Datasheet